Version 2.77

Part Description

LP21378-2   Catheter
In medicine, a catheter is a tube that can be inserted into a body cavity duct or vessel. Catheters thereby allow drainage or injection of fluids or access by surgical instruments. The process of inserting a catheter is catheterization. In most uses a catheter is a thin, flexible tube: a soft catheter; in some uses, it is a larger, solid tube: a hard catheter. Copyright Text is available under the Creative Commons Attribution/Share-Alike License. See http://creativecommons.org/licenses/by-sa/3.0/ for details. Source: Wikipedia, Catheter (Wikipedia)

Fully-Specified Name

Component
Guidance for placement of catheter^W contrast retrograde
Property
Find
Time
Pt
System
Abdomen>Biliary ducts+pancreatic duct
Scale
Doc
Method
RF

Additional Names

Short Name
RF Guided BD+PD Cath place W contr Retro

Associated Observations

81220-6 Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections

This panel contains the recommended sections for diagnostic imaging reports based on HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Releases 2.0 & 2.1.

LOINC Name R/O/C Cardinality Example UCUM Units
81220-6 Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections
Indent11329-0 History general O
Indent55115-0 Request (Radiology) O
Indent55111-9 Current imaging procedure descriptions Document O
Indent55114-3 Prior procedure descriptions O
Indent18834-2 Radiology Comparison study - observation O
Indent18782-3 Radiology Study observation (findings) R
Indent19005-8 Radiology - Impression O
Indent18783-1 Radiology Study recommendation O
Indent55110-1 Conclusions O
Indent55107-7 Addendum O
Indent18785-6 Radiology Reason for study O
Indent55108-5 Patient presentation O
Indent55109-3 Complications O
Indent55112-7 Summary O
Indent55113-5 Key images O

72230-6 Diagnostic imaging report - recommended C-CDA R1.1 sections

This panel contains the recommended sections for diagnostic imaging reports based on the HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Release 1.1.

LOINC Name R/O/C Cardinality Example UCUM Units
72230-6 Diagnostic imaging report - recommended C-CDA R1.1 sections
Indent18782-3 Radiology Study observation (findings) R
Indent55107-7 Addendum O
Indent55108-5 Patient presentation O
Indent55109-3 Complications O
Indent55110-1 Conclusions O
Indent55111-9 Current imaging procedure descriptions Document O
Indent11329-0 History general O
Indent55113-5 Key images O
Indent55114-3 Prior procedure descriptions O
Indent19005-8 Radiology - Impression O
Indent18834-2 Radiology Comparison study - observation O
Indent18785-6 Radiology Reason for study O
Indent18783-1 Radiology Study recommendation O
Indent55115-0 Request (Radiology) O
Indent55112-7 Summary O

Basic Attributes

Class
RAD
Type
Clinical
First Released
Version 2.04
Last Updated
Version 2.64
Change Reason
The scale has been changed from "Nar" to "Doc" to fit with the CDA model. Changed Component from "Guidance for catheterization^W contrast retrograde" to "Guidance for placement of catheter^W contrast retrograde" and System from "Biliary ducts+Pancreatic duct" to "Abdomen>Biliary ducts+pancreatic duct" for conformance with the LOINC/RadLex unified model.; Method of "XR.fluor" was changed to "RF". The LOINC/RadLex Committee agreed to use a subset of the two-letter DICOM modality codes as the primary modality identifier.
Order vs. Observation
Both
HL7® Attachment Structure
Implementation guide exists

Member of these Groups Get Info

LOINC Group Group Name
LG41823-2 Region imaged: Abdomen

Language Variants Get Info

Tag Language Translation
es-AR Spanish (Argentina) guía para cateterización^retrógrada:hallazgo:punto en el tiempo:conducto biliar+conducto pancreático:Narrativo:fluorografía
es-MX Spanish (Mexico) Orientación para la colocación del catéter ^ W contraste retrógrado:Tipo:Punto temporal:Abdomen> Conductos biliares + conducto pancreático:Documento:RF
it-IT Italian (Italy) Guida per posizionamento di catetere^Con contrasto retrogrado:Osservazione:Pt:Addome>Dotti biliari+dotto pancreatico:Doc:RF
Synonyms: Addome e Dotti biliari Dotti biliari e dotto pancreatico Osservazione Punto nel tempo (episodio) Radio-fluoroscopia Radiologia
pt-BR Portuguese (Brazil) Orientação para cateterização^com contraste via retrógrada:Achado:Pt:Via biliar+Ducto pancreático:Nar:Radioscopia
Synonyms: ; Cath guid; W contr retro; WC; Finding; Findings; Point in time; Random; BD+PDs; PD; BD+PDs; BDs; Biliary tract; Bile tract; Narrative; Report; Flr; Fluoro; Fluoroscopy; Xray; X-ray; Plain Films; Retro; Guid; Guided; Guide; c; Contrst; Contr; Contra; RADIOLOGY; Imaging; ERCP; Cholangiogram; Cholangiography; CAG; CHGM; Cholangiopancreatogram; Cholangiopancreatography
zh-CN Chinese (China) 旨在置入导管的引导^采用逆行性对比剂:发现:时间点:腹部>胆管类+胰管:文档型:放射荧光透视法
Synonyms: CAG CHGM Retro RF;放射荧光透视;放射线荧光透视法;放射线荧光透视;透视摄影;无线荧光透视法;无线荧光透视 临床文档型;临床文档;文档;文书;医疗文书;临床医疗文书 制导 反向 反向的 发现是一个原子型临床观察指标,并不是作为印象的概括陈述。体格检查、病史、系统检查及其他此类观察指标的属性均为发现。它们的标尺对于编码型发现可能是名义型,而对于叙述型文本之中所报告的发现,则可能是叙述型。;发现物;所见;结果;结论 增强剂 对比增强剂 导向 导尿管 导管 导管置入 成像;放射医学;放射学;显像 指导 指引 旨在(针对、用于)置入(安置、放置、摆位、安排)导管(导液管)的引导;旨在导管置入(置入术)的引导 时刻;随机;随意;瞬间 置入导管 胆管(复数);胆管 胆管(复数)+胰管;胆管 & 胰管;胆管(复数) & 胰管;胆管(复数)与胰管;胆管+胰管;胆管与胰管 胆管摄影像 胆管摄影图 胆管造影术 胆管造影术(Cholangiography,CAG) 胆管造影照片 胆管造影照片(Cholangiogram,CHGM,CAG) 胰的 胰胆管造影术 胰胆管造影照片 胰腺 胰腺的 腹;肚子 腹部(腹、肚子)+;腹部与 腹部(腹、肚子)>胆管类(胆管、胆道) 腹部(腹、肚子)>胆管类(胆管、胆道)+胰管(霍夫曼氏管、胰腺管、胰腺导管) 退行性 逆向的 逆行(Retrograde,Retro) 逆行性 逆行的 采用增强剂;采用对比增强剂 采用对比剂 多胆管 采用对比剂 多胆道 采用对比剂 胆管 采用对比剂 胆管+维尔松氏管 采用对比剂 胆管+霍夫曼氏管 采用对比剂 胆道 采用对比剂 胆道+维尔松氏管 采用对比剂 胆道+胰管 采用对比剂 胆道+霍夫曼氏管 采用对比剂 胆道类 采用逆行性(逆行)对比剂(增强剂、对比增强剂)

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=30892-4